21{25}1825-UPN-11-TKh.SO2 izm1TU 14-3R-1128-200769мPrice not specifiedPrice not specified1
22{26}1825-UPN-11-TKh.SO2 izm1TU 14-3R-1128-200760мPrice not specifiedPrice not specified1
23Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 325 x 8 pipe-to-48-09Г2С UHL Risp. = 9.0 Mpa1825-UPN-11-TKh.SO2 izm1TU 14-3R-1128-20075мPrice not specifiedPrice not specified1
24Tubes supplied according to TU 1381-012-05757848-2005 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². 630 x 10-09 pipe Ã2ñ-K50-UHL Risp. = 6.5 Mpa1825-UPN-11-TKh.SO2 izm1TU 1381-012-05757848-200534мPrice not specifiedPrice not specified1
25Tubes supplied according to TU 14-3 r-1128-2007, shall be constructed of ingot, subject to their control by the method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 57 x 4-09 Ã2ñ-to 48-UHL; RISP. = 20.0 Mpa1825-UPN-12-TKh.SO2TU 14-3R-1128-200798мPrice not specifiedPrice not specified1
26seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 shall be manufactured from rolled, forged, continuous or billet centrobezhnolitoj toughness pipe samples Menager (KCU) when testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 89 x 6-13 HFA-to 52-UHL; Pwork. = 7.5 Mpa; RISP. = 20 Mpa1825-UPN-12-TKh.SO2TU 1317-006.1-593377520-200368мPrice not specifiedPrice not specified2
27seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 shall be manufactured from rolled, forged, continuous or billet centrobezhnolitoj toughness pipe samples Menager (KCU) when testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 108 x 5-13 HFA-to 52-UHL; Pwork. = 7.5 Mpa; RISP. = 16.4 Mpa1825-UPN-12-TKh.SO2TU 1317-006.1-593377520-200321мPrice not specifiedPrice not specified2
28seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 shall be manufactured from billet, subject to their control by the method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 57 * 6-13HFA-to 52-UHL; Pwork. = 7 MPA; RISP. = 20 Mpa1825-UPN-12-TKh.SO2TU 1317-006.1-593377520-200342мPrice not specifiedPrice not specified2
29seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 shall be manufactured from billet, subject to their control by the method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 219 x 6-13 HFA-to 52-UHL; Pwork. = 7 MPA; RISP. = 20 Mpa1825-UPN-12-TKh.SO2TU 1317-006.1-593377520-200316мPrice not specifiedPrice not specified2
30seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 shall be manufactured from billet, subject to their control by the method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall be at least 30 j/cm ²; Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 40° c should be set to at least 20 Joules/cm2. 219 x 6-13 HFA-to 52-UHL; Pwork. = 0, 155MPa; RISP. = 14.2 Mpa1825-UPN-12-TKh.SO2TU 1317-006.1-593377520-200339мPrice not specifiedPrice not specified2
31seamless steel pipes, strength class to 52, delivered according to TU 006.1-1317-593377520-2003 must conform to technical requirements for them. Mechanical properties of metal pipes when tests should be specified in the specification. Impact strength material piping on samples Menager (KCU) at the testing temperature equal to minus 60° c shall be at least 30.0 j/cm2. Material toughness pipeline designs Sharpie (KCV) at the testing temperature equal to minus 40° c shall be at least 20.0 j/cm2. 108 tube x 6-13-HFA to 52-UHL Risp. = 30.41 Mpa1825-UPN-13a-TKh.SO2TU 1317-006.1-593377520-200326мPrice not specifiedPrice not specified2
32Tubes supplied according to TU r-14-3 1128-2007 shall be made of the ingot through SPL method in volume control 100% of the entire surface toughness Value material pipeline components on samples Menager (KCU) at a temperature of tests equal to minus 60° c shall be at least 30 j/cm2. The value of the toughness of the material parts of pipelines on samples Sharpie (KCV) at the testing temperature equal to minus 40° c. 57 tube x 4-09 Ã2ñ-to 48-UHL, Rzav. = 20.0 Mpa1825-UPN-14-TKh.SO2TU 14-3R-1128-200792мPrice not specifiedPrice not specified1
33Tubes supplied according to TU r-14-3 1128-2007 shall be made of the ingot through SPL method in volume control 100% of the entire surface toughness Value material pipeline components on samples Menager (KCU) at a temperature of tests equal to minus 60° c shall be at least 30 j/cm2. The value of the toughness of the material parts of pipelines on samples Sharpie (KCV) at the testing temperature equal to minus 40° c. Tube 89 x 4-09 Ã2ñ-to 48-UHL, Rzav. = 16.60 Mpa1825-UPN-14-TKh.SO2TU 14-3R-1128-200750мPrice not specifiedPrice not specified1
34Tubes supplied according to TU r-14-3 1128-2007 shall be made of the ingot through SPL method in volume control 100% of the entire surface toughness Value material pipeline components on samples Menager (KCU) at a temperature of tests equal to minus 60° c shall be at least 30 j/cm2. The value of the toughness of the material parts of pipelines on samples Sharpie (KCV) at the testing temperature equal to minus 40° c. Tube x 108 4-09 Ã2ñ-to 48-UHL, Rzav. = 13.60 Mpa1825-UPN-14-TKh.SO2TU 14-3R-1128-200739мPrice not specifiedPrice not specified1
35Tubes supplied according to TU r-14-3 1128-2007 shall be made of the ingot through SPL method in volume control 100% of the entire surface toughness Value material pipeline components on samples Menager (KCU) at a temperature of tests equal to minus 60° c shall be at least 30 j/cm2. The value of the toughness of the material parts of pipelines on samples Sharpie (KCV) at the testing temperature equal to minus 40° c. 219 x 6-09 pipe Ã2ñ-to 48-UHL, Rzav. = 10.1 Mpa1825-UPN-14-TKh.SO2TU 14-3R-1128-200756мPrice not specifiedPrice not specified1
36seamless steel tubes supplied according to TU 14-3 r-124-2012, made of rolled wrought iron, continuous or billet centrobezhnolitoj, must be tested for impact toughness. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². 108 tube x 6-13-HFA to 52-UHL Risp. = 21.00 Mpa1825-UPN-15-TKh.SO2 izm1TU 14-3R-124-201214мPrice not specifiedPrice not specified2
37seamless steel tubes supplied according to TU 14-3 r-124-2012, made of rolled wrought iron, continuous or billet centrobezhnolitoj, must be tested for impact toughness. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². Trumpet 159 x 8-13 HFA-to 52-UHL Risp. = 19.70 Mpa1825-UPN-15-TKh.SO2 izm1TU 14-3R-124-201241мPrice not specifiedPrice not specified2
38seamless steel tubes supplied according to TU 14-3 r-124-2012, made of rolled wrought iron, continuous or billet centrobezhnolitoj, must be tested for impact toughness. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². Pipe x 325 14-13-HFA to 52-UHL Risp. = 23.30 Mpa1825-UPN-15-TKh.SO2 izm1TU 14-3R-124-201215мPrice not specifiedPrice not specified2
39seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². 108 x 5 pipe-13HFA-to 52-UHL Risp. = 13.60 Mpa1825-UPN-15-TKh.SO2 izm1TU 1317-006.1-593377520-200371мPrice not specifiedPrice not specified2
40seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². Trumpet 159 x 8-13 HFA-to 52-UHL Risp. = 19.70 Mpa1825-UPN-15-TKh.SO2 izm1TU 1317-006.1-593377520-200336мPrice not specifiedPrice not specified2