No. | Name | Шифр | ГОСТ, ТУ, серия | Quantity | Unit of measure | Per unit price (show both prices) | Total limit price (show both prices) | Number of bidders |
41 | seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 46° c should be set to at least 20.0 j/cm ². Trumpet 219 x 8-13 HFA-to 52-UHL Risp. = 19.00 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 1317-006.1-593377520-2003 | 21 | м | Price not specified | Price not specified | 2 |
42 | Tubes supplied according to TU 14-3 r-1128-2007, made of rolled wrought iron, continuous or billet centrobezhnolitoj, must be tested for impact toughness. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². Pipe x 325 14-09 Ã2ñ-to 48-UHL Risp. = 16.00 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 72 | м | Price not specified | Price not specified | 1 |
43 | Tubes supplied according to TU 14-3 r-1128-2007, made of rolled wrought iron, continuous or billet centrobezhnolitoj, must be tested for impact toughness. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². Pipe .0õ20-426 09g2s-to 48-UHL Risp. = 18.20 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 4 | м | Price not specified | Price not specified | 1 |
44 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 57 tube x 4-09 Ã2ñ-to 48-UHL Risp. = 26.70 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 50 | м | Price not specified | Price not specified | 1 |
45 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 108 tube x 6-09 Ã2ñ-to 48-UHL Risp. = 21.00 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 89 | м | Price not specified | Price not specified | 1 |
46 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 159 x tube 5-09 Ã2ñ-to 48-UHL Risp. = 14.00 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 24 | м | Price not specified | Price not specified | 1 |
47 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 219 x tube 6-09 Ã2ñ-to 48-UHL Risp. = 10.10 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 62 | м | Price not specified | Price not specified | 1 |
48 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². Pipe 273 x 7-09 Ã2ñ-to 48-UHL Risp. = 9.40 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 12 | м | Price not specified | Price not specified | 1 |
49 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 325 tube x Ã2ñ 8-09-to 48-UHL Risp. = 9.00 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 20 | м | Price not specified | Price not specified | 1 |
50 | Tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 426 x tube 8-09 Ã2ñ-to 48-UHL Risp. = 6.80 Mpa | 1825-UPN-15-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 30 | м | Price not specified | Price not specified | 1 |
51 | Pipe steel hot-rolled seamless pipes, steel 09Г2С GOST 19281-89 Ø 57 x 3.0 | 1825-UPN-15-TS.SO2 | GOST 8732-78 | 5 | м | Price not specified | Price not specified | 1 |
52 | Tubes supplied according to TU 14-3 r-1128-2007, shall be constructed of rolled wrought iron, continuous or centrobezhnolitoj. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² tests on samples of a Sharpie (KCV) produce at a temperature of minus 40° 57 Tube x 4 09 Ã2ñ r exec = 20.00 Mpa | 1825-UPN-19-TKh.SO2 | TU 14-3R-1128-2007 | 35 | м | Price not specified | Price not specified | 1 |
53 | Tubes supplied according to TU 14-3 r-1128-2007, shall be constructed of rolled wrought iron, continuous or centrobezhnolitoj. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² tests on samples of a Sharpie (KCV) produce at a temperature of minus 40° Pipe 89 x 4.0 09Г2С Risp = 16.84 Mpa | 1825-UPN-19-TKh.SO2 | TU 14-3R-1128-2007 | 34 | м | Price not specified | Price not specified | 1 |
54 | Tubes supplied according to TU 14-3 r-1128-2007, shall be constructed of rolled wrought iron, continuous or centrobezhnolitoj. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² tests on samples of a Sharpie (KCV) produce at a temperature of minus 40° Pipe 108 x 4.0 09Г2С Risp = 12.0 Mpa | 1825-UPN-19-TKh.SO2 | TU 14-3R-1128-2007 | 11 | м | Price not specified | Price not specified | 1 |
55 | Tubes supplied according to TU 14-3 r 1128-2007 must be tested for impact toughness in accordance with TU. Testing on samples of KSV produce at a temperature of minus 60 degrees Celsius. Tube 89 x 4 09 Ã2ñ Risp = 16.84 Mpa | 1825-UPN-20-TKh.SO2 | TU 14-3R-1128-2007 | 4 | м | Price not specified | Price not specified | 1 |
56 | Tubes supplied according to TU 14-3 r-1128-2007, shall be constructed of ingot, subject to their control by the method of ULTRASOUND in the amount of 100% of the entire surface toughness pipeline material samples Menager (KCU) at the testing temperature, equal minus 60° c shall be at least 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40° c Pipe 57x4-flanged-to 48-UHL | 1825-UPN-29-TKh.SO2 | TU 14-3R-1128-2007 | 5 | м | Price not specified | Price not specified | 1 |
57 | seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 must be made of rolled wrought iron, continuous or centrobezhnolitoj. Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 50° c shall have a value of not less than 98.0 j/cm ². pipe 57 x 4-13 HFA Risp = 20.00 Mpa | 1825-UPN-35-TKh.SO2 | TU 1317-006.1-593377520-2003 | 5 | м | Price not specified | Price not specified | 2 |
58 | seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 must be made of rolled wrought iron, continuous or centrobezhnolitoj. Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 50° c shall have a value of not less than 98.0 j/cm ². pipe 89 x 5-13 HFA Risp = 21.26 Mpa | 1825-UPN-35-TKh.SO2 | TU 1317-006.1-593377520-2003 | 20 | м | Price not specified | Price not specified | 2 |
59 | seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 must be made of rolled wrought iron, continuous or centrobezhnolitoj. Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 50° c shall have a value of not less than 98.0 j/cm ². pipe 159 x 6-13 HFA Risp = 14.05 Mpa | 1825-UPN-35-TKh.SO2 | TU 1317-006.1-593377520-2004 | 30 | м | Price not specified | Price not specified | 2 |
60 | seamless steel tubes supplied according to ТУ 1317-006.1-593377520-2003 must be made of rolled wrought iron, continuous or centrobezhnolitoj. Toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 50° c shall have a value of not less than 98.0 j/cm ². pipe x 325 14-13 HFA Risp = 16.11 Mpa | 1825-UPN-35-TKh.SO2 | TU 1317-006.1-593377520-2005 | 100 | м | Price not specified | Price not specified | 2 |