1 | Tubes supplied according to TU 14-3 r-1128-2007, shall be supplied in heat treated condition and be tested for shock vjayzkost in accordance with TU 14-3, r-1128-2007. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40 c, Pipe 57 x 4-09 Ã2ñ-to 48-UHL | 1825-UPN-4-TKh.SO2 | TU 14-3R-1128-2007 | 0,5 | м | Price not specified | Price not specified | 1 |
2 | Tubes supplied according to TU 14-3 r-1128-2007, shall be supplied in heat treated condition and be tested for shock vjayzkost in accordance with TU 14-3, r-1128-2007. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40 c, Pipe 57 x 4-09 Ã2ñ-to 48-UHL | 1825-UPN-5-TKh.SO2 | TU 14-3R-1128-2007 | 0,5 | м | Price not specified | Price not specified | 1 |
3 | Tubes supplied according to TU r-14-3 1128-2007 should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40 c, Pipe 57 x 4-09 Ã2ñ-to 48-UHL Risp. = 26.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 14-3R-1128-2007 | 110 | м | Price not specified | Price not specified | 1 |
4 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Pipe 57 x 5-13 HFA-to 52-UHL Risp. = 34.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 210 | м | Price not specified | Price not specified | 2 |
5 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 89 x 5-13 HFA-to 52-UHL Risp. = 25.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 13 | м | Price not specified | Price not specified | 2 |
6 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 108 x 5-13 HFA-to 52-UHL Risp. = 21.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 36 | м | Price not specified | Price not specified | 2 |
7 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 159 x 6-13 HFA-to 52-UHL Risp. = 14.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 30 | м | Price not specified | Price not specified | 2 |
8 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 219 x 6-13 HFA-to 52-UHL Risp. = 10.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 120 | м | Price not specified | Price not specified | 2 |
9 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c m Pipe 273 x 8-13 HFA-to 52-UHL Risp. = 10.00 Mpa | 1825-UPN-6-TKh.SO2 | TU 1317-006.1-593377520-2003 | 80 | м | Price not specified | Price not specified | 2 |
10 | Pipes supplied by TU 14-3 r-1128-2007 should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40 c, Pipe 57 x 4-13 HFA-to 48-UHL Risp. = 26.00 Mpa | 1825-UPN-7-TKh.SO2 | TU 14-3R-1128-2007 | 4 | м | Price not specified | Price not specified | 1 |
11 | Tubes supplied according to TU r-14-3 1128-2007 should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 40 c, 108 x Tube 6-13 HFA-to 48-UHL Risp. = 21.01 Mpa | 1825-UPN-7-TKh.SO2 | TU 14-3R-1128-2007 | 16,5 | м | Price not specified | Price not specified | 1 |
12 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Pipe 57 x 5-13 HFA-to 52-UHL Risp. = 34.00 Mpa | 1825-UPN-7-TKh.SO2 | TU 1317-006.1-593377520-2003 | 1,5 | м | Price not specified | Price not specified | 2 |
13 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 89 x 5-13 HFA-to 52-UHL Risp. = 25.00 Mpa | 1825-UPN-7-TKh.SO2 | TU 1317-006.1-593377520-2003 | 9 | м | Price not specified | Price not specified | 2 |
14 | Tubes supplied according to ТУ 1317-006.01-593377520-2003, should izgotovlivatsja from ingot through SPL method in volume control 100% of the entire surface. Material toughness pipeline components on samples Menager (KCU) at the testing temperature equal to minus 60 c, shall be not less than 30.0 j/cm2 Tests on samples Sharpie (KCV) run at a temperature of minus 46 c Trumpet 108 x 6-13 HFA-to 52-UHL Risp. = 21.00 Mpa | 1825-UPN-7-TKh.SO2 | TU 1317-006.1-593377520-2003 | 7 | м | Price not specified | Price not specified | 2 |
15 | Tubes supplied according to TU 14-3 r-1128-2007, TU1317-006.1-593377520-2003 should be tested for impact toughness in accordance with Tu r-14 -3 1128-2007, TU1317-006.1-593377520-2003 impact toughness test to produce at a temperature of minus 60 0 c 57 tube x 4-09 Ã2ñ Risp = 20.0 Mpa | 1825-UPN-9-TKh.SO2 | TU 14-3R-1128-2007 | 27 | м | Price not specified | Price not specified | 1 |
16 | Tubes supplied according to TU 14-3 r-1128-2007, TU1317-006.1-593377520-2003 should be tested for impact toughness in accordance with Tu r-14 -3 1128-2007, TU1317-006.1-593377520-2003 impact toughness test to produce at a temperature of minus 60 0 c Tube 89 x 6-13 HFA Risp = 13.78 Mpa | 1825-UPN-9-TKh.SO2 | TU 1317-006.1-593377520-2003 | 61,5 | м | Price not specified | Price not specified | 2 |
17 | Tubes supplied according to TU 14-3 r-1128-2007, TU1317-006.1-593377520-2003 should be tested for impact toughness in accordance with Tu r-14 -3 1128-2007, TU1317-006.1-593377520-2003 impact toughness test to produce at a temperature of minus 60 0 c Pipe x 108 6-09 Ã2ñ Risp = 21.01 Mpa | 1825-UPN-9-TKh.SO2 | TU 14-3R-1128-2007 | 23,5 | м | Price not specified | Price not specified | 1 |
18 | Tubes supplied according to TU 14-3 r-1128-2007, TU1317-006.1-593377520-2003 should be tested for impact toughness in accordance with Tu r-14 -3 1128-2007, TU1317-006.1-593377520-2003 impact toughness test to produce at a temperature of minus 60 0 c Trumpet 219 x 6-09 Ã2ñ Risp = 10.11 Mpa | 1825-UPN-9-TKh.SO2 | TU 14-3R-1128-2007 | 26 | м | Price not specified | Price not specified | 1 |
19 | Tubes supplied according to TU 14-3 r-1128-2007, TU1317-006.1-593377520-2003 should be tested for impact toughness in accordance with Tu r-14 -3 1128-2007, TU1317-006.1-593377520-2003 impact toughness test to produce at a temperature of minus 60 0 c Trumpet 219 x 6-13 HFA Risp = 10.11 Mpa TTruby | 1825-UPN-9-TKh.SO2 | TU 1317-006.1-593377520-2003 | 27,5 | м | Price not specified | Price not specified | 2 |
20 | supplied TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². 57 tube x 4-09 Ã2ñ-to 48-UHL Risp. = 20.0 Mpa sake Pipes supplied by TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the entire surface. Impact strength of pipes on samples Menager (KCU) at the testing temperature equal to minus 60° c shall not be less than 30.0 j/cm ² toughness pipe on designs Sharpie (KCV) at the testing temperature equal to minus 60° c should be set to at least 20.0 j/cm ². Pipe 108 x 4-09 Ã2ñ-to 48-UHL Risp. = 13.7 Mpa but the tubes supplied according to TU 14-3 r-1128-2007 of ingot, must pass the control method of ULTRASOUND in the amount of 100% on the ent | 1825-UPN-11-TKh.SO2 izm1 | TU 14-3R-1128-2007 | 141 | м | Price not specified | Price not specified | 1 |