Per-item bid submission: | Not applicable. Proposal shall cover the entire lot. |
Hide prices and bidders' names during bids submission period: | Yes |
Alternative bids Alternative bid is a bid, of which the terms and conditions differ from those established in the bid-related documents. : | Yes |
Upload of bid-related documents required Bids not supported with documentation will not be considered. : | Yes |
Contract performance security: | Заказчик осуществляет оплату услуг при наличии следующих документов:
- при общей стоимости услуг (работ) 3 000 000 рублей и более в случае предоплаты прилагается банковская гарантия;
- счет;
- акт сдачи-приемки услуг (работ).
При отсутствии указанных документов Заказчик не совершает платежи и не несет ответственности за неисполнение своих обязательств. |
Payment terms: | The customer pays for the services of the Contractor within 90 days from the moment of signing the acceptance certificate of services. The works are accepted after the Contractor has completed the repair work and with the execution of the commissioning certificate of the frequency converter. |
Delivery terms: | Sending the frequency converter for repair and from repair by means of the Contractor. |
Georeferencing: | - st. Ivaschenko, 9 A / 1,
Zheleznogorsk-Ilimsky,
Irkutsk region,
665651
- Irkutsk region, Zheleznogorsk-Ilimsky, Promyshlennaya str., d 5 |
Comments: 1. The commercial proposal must contain the total cost, confirmed by the calculation for the provision of services.
2. Technical condition of the object of repair:
- on the 6SE7033-5HH84-1HH0 board (board on the input buses), the destruction of the three-phase bridge of the VUO34-18N01 brand (45A, 1800V) is visually observed. The tracks and contacts on its body from the AC side burned out.
- on the thyristor control board of the DC unit (6SE7031-7HH84-1HJ0), traces of metallization from the short-circuit are visually observed. Tracks in thyristor control circuits are damaged.
- on power modules of the SKKT-273 / 16F brand, thyristors in the anode group are short-circuited in all three phases.
- exactly opposite the resistors connected between the terminals of the three-phase bridge specified in paragraph 1 and the terminals D / L +, D / L-, the insulation between the plates "+" and "-" of the DC link melted. |
Venue of bidding: | This call for bids is held in electronic form on the e-marketplace of B2B-Center group (www.b2b-center.ru). Bids shall be submitted in the form of e-document. |
Сотрудник службы безопасности (ФИО, контактные данные): | Главный специалист ОЭБ ДКБ Рынин Сергей Николаевич, тел.: (39566)96-035 эл. почта: Sergey.Rynin@korgok.ru,
специалист ОЭБ ДКБ Кондрашов Антон Юрьевич, тел.: (39566)96-810 эл. почта: Anton.Kondrashov@korgok.ru |
Контактное лицо: | Фокеев Михаил Александрович тел.: 8(39566) 96-094 эл. почта: Mikhail.Fokeev@korgok.ru |
E-signature info: | Signed with e-signature |